Sunday, 21 January 2018

NATIONAL AMBIENT AIR QUALITY STANDARDS :- INDIA

Notification G.S.R - 826(E) dated
16th November, 2009
Ref: - The Environment (Protection) Seventh Amendment Rule 2009
SCHEDULE VII: - NATIONAL AMBIENT AIR QUALITY STANDARDS :-INDIA
[See Rule 3(3B) of EP Rule 1986]
SCHEDULE VII of Environment Protection Rule 1986
SN

Pollutants


Time Weighted Average

Concentrations in Ambient Air
Industrial, Residential, Rural and Other Area
Ecologically Sensitive Area (Notified by Central Govt.)
Methods of Measurement
(1)
(2)
(3)
(4)
(5)
(6)
1
Sulphur Di-oxide, SO,  (µg/m³)
Annual*
24hours**
50
80
20
80
-Improved West & Gaeke.
-Ultraviolet Fluorescence.
2
Nitrogen Di-oxide, NO,  (µg/m³)
Annual*
24hours**
40
80
30
80
-Modified Jacob & Hoehhelser (Na-Arsenite).
-Chemiluminescence.
3
Particulate Matter (Size less than 10µm) or  PM₁₀,  (µg/m³)
Annual*
24hours**
60
100
60
100
-Gravimetric
-TOEM
-Beta Attenuation
4
Particulate Matter (Size less than 2µm) or  PM.,  (µg/m³)
Annual*
24hours**
40
60
40
60
-Gravimetric
-TOEM
-Beta Attenuation
5
Ozone, Oᴣ, (µg/m³)
8hours**
1hour**
100
180
100
180
-UV Photometric
- Chemiluminescence
-Chemical Method
6
Lead, Pb, (µg/m³)
Annual*
24hours**
0.5
1.0
0.5
1.0
-AAS/ICP Method after sampling on EPM 2000 or equivalent filter paper.
- ED-XRF using Teflon Filter
7
Carbon Monoxide, CO, (µg/m³)
8hours**
1hour**
02
02
04
04
-Non-Dispersive Infrared (NDIR) Spectroscopy.
8
Ammonia, NHᴣ, (µg/m³)
Annual*
24hours**
100
400
100
400
- Chemiluminescence
-Indophenol Blue Method
9
Benzene, C6H6, (µg/m³)
Annual*


05
05
-Gas Chromatography based continuous analyser.
- Adsorption &Desorption followed by GC analysis.
10
Benzo Pyrene (BaP)- Particulate Phase only, (ng/m³)
Annual*

01

01

-Solvent extraction followed by HPLC/GC analysis

11
Arsenic (As), (ng/m³)
Annual*

06

06

-AAS/ICP Method after sampling on EPM 2000 or equivalent filter paper.
12
Nickel, (Ni), (ng/m³)
Annual*

20

20


-AAS/ICP Method after sampling on EPM 2000 or equivalent filter paper.








* Annual arithmetic mean of minimum 104 measurements in a year at a particular site twice a week 24 hourly at uniform intervals.
** 24 hourly or 8 hourly or 01 hourly monitored values, as applicable, shall be complied with 98% of the time in a year. 2% of the time they may exceed the limits but not on two consecutive days of monitoring.
Note- Whenever & Wherever monitoring results of two consecutive days of monitoring exceeds the limits specified above for the respective category, it shall be considered adequate reason to institute regular or continuous monitoring & further investigation.